Yes, you can use 10 AWG copper conductors with a 20 ampere breaker. The smallest size conductors you could use with a 20 ampere breaker, are 12 AWG copper conductors. There’s no problem using larger conductors, other than cost to you, and difficulties associated with working with thicker conductors.
How far can you run 10 gauge wire for 20 amps?
How Far Can You Run 10 Gauge Wire? You can run a 10 gauge wire up to 85 feet on a 20 amp circuit. If you opt to use this type of wire on a 15 amp circuit, it can run up to 115 feet. After these distances, the circuit will go over the recommended 3% voltage drop.
Is it OK to use 10 gauge wire for outlets?
The minimum wire size for a 30-amp, 240-volt circuit is 10-gauge, but to prevent poor performance because of voltage drop, you should consider upgrading to 8-gauge if the outlet is far from the panel. For a 50-amp circuit, you need a 6-gauge wire at a minimum.
What size wire should a 20 amp receptacle use?
For a 20-Amp circuit use #12 copper wire (or #10 copper-clad aluminum wire). The fuse or circuit breaker feeding this circuit is rated for 20 amps.
How many amps is #10 wire good for?
Size & AMP Ratings
NM, TW, & UF WIRE (Copper Conductor) | SE CABLE (Copper Conductor) |
---|---|
14 AWG – 15 AMPS | 8 AWG – 50 AMPS |
12 AWG – 20 AMPS | 6 AWG – 65 AMPS |
10 AWG – 30 AMPS | 4 AWG – 85 AMPS |
8 AWG – 40 AMPS | 2 AWG – 115 AMPS |
When should I use 20 amp outlets?
Large consumers, especially kitchen appliances, such as microwaves, blenders and toasters, need a dedicated 20 amp circuit, to ensure a constant energy flow, which means they cannot share the circuit with other devices.
When should I use 10 gauge wire?
“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”
Can I use 10 gauge wire on a 15 amp outlet?
Only for 15 Amp items, 14 or 888-282-0465 888-282-0465 888-282-0465, or smaller for 20 Amp ones. The #10 wire wouldn’t fit into a back wired receptacle and wouldn’t work with screw terminals or devices with wired connections.
Can you mix 12 and 10 gauge wire?
It would be fine (if you follow all the rules for sub-panels) to run 10 gauge wire protected by a 30A breaker to a sub-panel and then run 12 gauge wires each protected by a 20A breaker from the sub-panel.
What is 20amp wire?
Why Wire Gauge Is Important
Wire Use | Rated Ampacity | Wire Gauge |
---|---|---|
Low-voltage lighting and lamp cords | 10 amps | 18-gauge |
Extension cords (light-duty) | 13 amps | 16-gauge |
Light fixtures, lamps, lighting circuits | 15 amps | 14-gauge |
Kitchen, bathroom, and outdoor receptacles (outlets); 120-volt air conditioners | 20 amps | 12-gauge |
Can you run 14 gauge wire on a 20 amp circuit?
14 AWG must be protected at 15A, according to NEC 240.4(D)(3). 14 AWG can’t be used on a circuit with a 20A breaker. The screw terminals are the better choice if you want to put 15 Amp receptacle on a 20 Amp circuit with 12 gauge wire. You can use the side terminals.
Can I mix 12 and 14 gauge wire on a 20 amp circuit?
Generally speaking, #12 is good for 20A and #14 is only good for 15A. So if you have a 15A circuit, you could mix them with no problem. However if you have a 20A circuit, you can’t use #14 at all.
What is 10 2 Romex used for?
The following NEC regulations apply to Romex conductors:
Wire Gauge or Type | Rated Amperage | Common Uses |
---|---|---|
10-2 Romex | 30 A | Electric water heater, baseboard heaters |
10-3 Romex | 30 A | Electric Clothes Dryer |
6/3 Cu Range Cable | 50 A | Range, Heatpump, On-Demand Electric Water heater |
2 Gauge Copper | 100 A | Central Electric Heat |
How far will 10 gauge wire carry 30 amps?
#10 is normally used for short runs of 30 amps. With 150 feet though, I’d opt at least for #8, and maybe even #6. Go to any standard wire table to find the ohmage of the wire size.
How many receptacles can be on a 20 amp circuit?
The answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.
How many amps can a 10 gauge wire handle at 12 volts?
Maximum current (amps) in a 12V electrical circuit vs. size (AWG) and length of wire.
American Wire Gauge (#AWG) | ||
---|---|---|
Length (feet) | Maximum Current (amps) | |
50 | 10 | 8 |
60 | 10 | 6 |
70 | 10 | 6 |